Direct answer: An energy management and unit-product energy consumption page cannot just say "green factory, energy saving, consumption falling." It should state how energy is metered and collected, how comprehensive energy consumption is converted to standard coal, the boundary and denominator for unit-product energy, whether the company is a key energy-using entity, the management system and responsible person, energy audits and online monitoring, the baseline and savings calculation for retrofit projects, how green power and certificates are used, and what must not be published. Otherwise, when a customer or auditor asks "how is your comprehensive energy calculated, what is the denominator, which version of the conversion factor, is there a baseline for the savings," the answer is a percentage with no source.
This guide is for energy, equipment, EHS, finance, procurement, supplier-management, and website teams at manufacturers in Changzhou and nearby industrial areas. It explains how to build and accept an energy management and unit-product energy consumption page. Information is current to 2026-11-02. It is a review of public regulations, standards, and project practice, not energy-audit, energy-diagnosis, carbon-accounting, or legal advice; specific metering, conversion factors, limit standards, energy-saving review, and data boundaries depend on current rules, standards, the competent authority, and customer requirements.
An energy number is usable only if three things are clear: metering is segregated and tiered, conversion factors have a source, and the denominator (output/value) uses the same boundary. Unit-product energy is not simply "total energy divided by output": boundary, conforming-product basis, product mix, and season all change the result. Savings need a baseline and adjustments—reduced output, shutdowns, or cooler weather are not energy savings; a green certificate is a consumption certificate, not evidence of "zero carbon."
How does the energy page relate to carbon-footprint, ESG, maintenance, and supplier-onboarding pages?
The carbon-footprint page answers "how much does one product emit"; the ESG page answers "company-level environmental, social, and governance performance"; the maintenance page answers "how equipment is serviced"; the supplier-onboarding page answers "how customers audit us"; the energy page answers "how much energy is used, how it is metered, how much per unit of product, what retrofits were done, and how the data is proven." Energy data is the denominator under carbon accounting and ESG: if the energy page cannot explain itself, the carbon and ESG numbers are hard to audit.
The common break is: only a master electricity meter exists, with no workshop or key-equipment sub-metering; electricity bills serve as the energy ledger, while water, gas, steam, and compressed air are not tracked; a conversion factor is copied online without version or whether it is calorific/equivalent value; the output used for unit-product energy is unclear (warehouse receipt vs sales); a retrofit claims "20% savings" with no baseline, boundary, or verification; a stack of green certificates becomes "100% green power, zero-carbon factory." A page that states metering, basis, boundary, and evidence gives customers and auditors something to check.
| Page/entry | Answers | Audience | Cannot replace |
|---|---|---|---|
| Energy page | Metering, comprehensive energy, unit product, retrofits, green power | Customer audit, EHS, energy | The energy audit report itself |
| Carbon footprint | Product-level emissions, boundary, factors, verification | Customer, engineering | Company energy statistics |
| ESG page | Company-level environmental, social, governance data | Customer, investor | Metering and ledgers |
| Maintenance page | Inspection, servicing, efficiency maintenance | Equipment, production | Metering and conversion |
| Supplier onboarding | Qualifications, audit questionnaire, EHS | Procurement, customer | Energy data and evidence |
This page map is editorial; metering and statistics obligations are in Article 27 of the Energy Conservation Law.
How should energy meters be configured and data collected?
Configure by "energy type × tier": electricity, water, natural gas, steam, compressed air, and cooling/heating metered separately; master meters, workshop/line meters, and key-equipment meters tiered; meters must be provided and used in accordance with the law and verified; data needs a collection frequency, meter-reading/remote records, exception handling, and a register. With only a master meter you can compute a total but cannot locate which line or machine consumes energy, and cannot support unit-product energy or a retrofit baseline.
Article 27 of the Energy Conservation Law requires energy-using entities to strengthen energy metering management, provide and use verified energy meters as required, establish energy-consumption statistics and analysis, meter and count each energy type separately, and ensure data is true and complete. "Having a meter" is not "having usable data": calibration drift, wrong multipliers, changed reading boundaries, temporary wiring, and un-deducted external supply can all distort conversion and unit-product energy downstream.
| Tier/type | What to do | Evidence | Common gap |
|---|---|---|---|
| Master meter | Electricity/water/gas/steam total, reconciled to bills | Bill/remote | Electricity bill only |
| Workshop/line | Tiered metering and allocation rules | Sub-meter register | Estimated by area |
| Key equipment | Separate metering for high-consumption equipment | Meter/collection | Buried in total |
| Meter status | Verified, within validity | Verification certificate | Expired |
| Data management | Frequency, reading, exceptions, revisions | Raw records | Back-filled later |
| Transfer/external supply | Deduct or list separately, avoid double counting | Settlement | Counted twice |
Metering requirements are in Article 27 of the Energy Conservation Law; specific configuration follows industry standards and company policy.
How are energy types, conversion factors, and comprehensive energy calculated?
List energy types and physical quantities, convert each to standard coal with one consistent factor, and sum to comprehensive energy consumption; boundary, scope, and conversion requirements follow GB/T 2589-2020. State the factor source, version, and whether it is calorific or equivalent value—do not use one factor for electricity and another for gas, and do not switch versions year over year without explanation. Whether external supply, transfers, inventory changes, and energy used as feedstock are deducted must follow the standard and the stated basis.
Comprehensive energy is not "adding up bills": electricity, steam, natural gas, water (whether included depends on the basis), and compressed air (usually converted from electricity) must be separated into primary and secondary energy, avoiding double counting electricity and the compressed air it produces. A factor version change affects year-on-year results directly; the page should say "same basis as last period / adjusted and explained," not just show a decline.
| Item | What to state | Basis | Common gap |
|---|---|---|---|
| Energy types | Physical quantities of electricity, water, gas, steam, cooling/heating | Bills/meters | Omissions |
| Factors | Source, version, calorific/equivalent value | GB/T 2589 | Copied online |
| Boundary | Plant/process/product, external supply included? | Standard/policy | Boundary drift |
| Double counting | Electricity vs compressed air, steam vs waste heat | Conversion | Added twice |
| Deductions | External supply, transfers, feedstock | Settlement/standard | Not deducted |
| Year-on-year | Version changes, adjustments explained | Workpaper | Percentage only |
Principles, boundary, and conversion are in GB/T 2589-2020; specific factors follow the current version of the standard.
How should unit-product energy be calculated and compared?
Unit-product energy = comprehensive energy in the period ÷ conforming output in the same period (or the industry-specified basis). The key is three matching bases: same boundary (plant/process), same output (conforming product, unit, period), and same product mix (multi-product sites split by product or use a comparable basis). Compare with own history, industry benchmarks, and the applicable unit-product energy limit standard—never compare figures with different boundaries or product mixes directly.
Multi-product, small-batch plants are most easily distorted: using gross output value as the denominator lets price swings "create" savings; switching between warehouse receipt and sales distorts inventory effects; including or excluding outsourced/subcontracted semi-finished goods changes the boundary. Define the accounting unit first (plant/line/single product), fix the denominator basis, and explain output, mix, and seasonal changes in the analysis. The page can give the formula and basis, but must not promise "X% reduction every year."
| Element | What to define | Evidence | Common gap |
|---|---|---|---|
| Unit | Plant/line/single product | Energy policy | Mixed together |
| Boundary | Processes, outsourcing, external supply | Boundary map | Boundary changes |
| Denominator | Conforming output, unit, period | Production reports | Output/value mixed |
| Multi-product | Split by product or comparable conversion | Conversion method | Simple average |
| Comparison | History, peers, limit standard | Benchmark record | Only vs last year |
| Explanation | Mix, season, orders, maintenance | Analysis report | Number only |
Limit standards and benchmarking are in Article 17 of the Key Energy-Using Entity Measures; specific limits follow the current mandatory national standards for the industry.
What extra obligations apply to key energy-using entities?
Entities with comprehensive energy consumption of 10,000 tonnes of standard coal or more per year are key energy-using entities; those between 5,000 and 10,000 tonnes that are designated by the relevant State Council department or the provincial energy authority also qualify. Key entities must prepare and implement annual energy-saving plans and measures, establish an energy management system, set up a leading group and appoint an energy management officer (filed), conduct energy audits and submit reports, build an online energy-consumption monitoring system, submit an annual energy-use report, and comply with mandatory unit-product energy limits and efficiency standards.
"We are under 10,000 tonnes" still requires checking whether you have been designated, and whether customers or the group apply key-entity requirements. The obligations are not "one form": the energy-use report covers consumption, efficiency, target completion, benefit analysis, and measures; the authority reviews it and may conduct on-site investigation, efficiency testing, order an energy audit, and set a rectification deadline. The page can say "an energy management system is in place and reports are submitted on time," but must not turn "submitted" into "approved."
| Obligation | What to do | Basis | Common gap |
|---|---|---|---|
| Designation | ≥10,000 tce; or 5,000–10,000 tce if designated | Art. 52 | Not checked |
| Plan | Annual plan and measures, targets decomposed | Arts. 6, 8 | Slogans only |
| Organisation | Leading group, officer, post, filing | Art. 10 | Nominal |
| Audit | Conduct, report, rectify | Art. 14 | Not done for years |
| Online monitoring | Build as required | Art. 15 | Not connected |
| Annual report | Consumption, efficiency, target, benefit, measures | Art. 53 | Late/incomplete |
| Limits/benchmark | Mandatory limits, efficiency benchmarking | Art. 17 | No comparison |
Designation and reporting are in Articles 52–55 of the Energy Conservation Law; specific duties are in the Key Energy-Using Entity Measures.
How should the energy management system, organisation, and training be implemented?
The system should cover metering and statistics, energy quotas and assessment, economic operation of equipment, procurement and phase-out, retrofit project management, audits and rectification, and training and rewards/penalties. Organisationally, there must be an energy management officer and post with clear duties; key entities also need a leading group headed by top management, with the officer and managers filed. Training needs records—not a line in the policy saying "strengthen training."
"Having a system" and "the system running" are different. Auditors look at: whether the energy management officer has the relevant expertise and title and is filed; whether energy targets are decomposed to workshops/teams and assessed; whether economic operating parameters are monitored; whether there is a plan to phase out obsolete equipment; whether retrofit projects have approval, acceptance, and effect verification; whether training has attendance and assessment. The page can say "an energy management system is established and operating," but the records must exist.
| Module | What to do | Evidence | Common gap |
|---|---|---|---|
| System | Metering, statistics, quotas, assessment, procurement, retrofits | Policy | One general document |
| Organisation | Leading group, officer, post, filing | Appointment/filing | Nominal |
| Targets | Decomposed to workshop/team, assessed | Assessment form | Company level only |
| Equipment | Economic operation, phase-out, maintenance | Register/plan | Run to failure |
| Training | Job training, assessment, records | Attendance/test | No records |
| Internal audit | Self-check, rectification, closure | Audit report | Not closed |
System and organisation requirements are in Articles 6–10 of the Key Energy-Using Entity Measures; the officer requirement is in Article 55 of the Energy Conservation Law.
How should retrofit savings be calculated and proven?
For each retrofit, state the current situation and problem, scope of work, investment, implementation period, baseline period, boundary, savings calculation method, verification approach, payback, and risks. Savings = baseline energy − post-retrofit energy, adjusted for output, product mix, weather, and operating hours; do not replace measurement with "nameplate power × hours," and do not count reduced output, shutdowns, or order changes as savings. Track at least one full cycle after the retrofit and keep metering data and a comparison analysis.
"Expected 20% savings" is the most common empty claim: no baseline, no boundary, no adjustment, nothing for the customer to verify. The right approach: define a baseline period (3–12 consecutive months before the retrofit, covering seasons), define the boundary (single machine/line/plant), compare on the same basis after the retrofit, and use third-party measurement and verification where needed. State the unit, conversion basis, and whether it counts as carbon reduction separately—savings are not carbon reductions; the latter also depends on energy type and emission factors.
| Element | What to state | Evidence | Common gap |
|---|---|---|---|
| Baseline | Pre-retrofit energy, output, conditions, season | Meter/bill | Guessed |
| Boundary | Machine/line/plant, which energy types | Boundary map | Unclear |
| Measures | Scope, equipment, control strategy | Plan/contract | "Upgrade" only |
| Calculation | Formula, adjustments | Workpaper | No output adjustment |
| Verification | Post-retrofit tracking, measurement | Comparison report | Theoretical only |
| Economics | Investment, payback, O&M change | Financial model | Savings without cost |
Retrofit and benchmarking requirements are in Articles 16 and 17 of the Key Energy-Using Entity Measures; the savings method follows the project agreement and applicable standards.
How should green power, green certificates, and renewables be used and described?
Separate four things: self-generated renewables, green-power trading, green-certificate purchase, and energy-performance contracting. A green certificate is evidence of renewable electricity consumption—it proves "how much green power was purchased," not that the company is "zero carbon." Whether it can be used in a customer's carbon accounting, which emission factor applies, and whether it double-counts green-power trading must follow the applicable rules and customer requirements. State the volume, period, certificate number or transaction record, and whether it overlaps other claims.
"100% green power" and "zero-carbon factory" are high-risk: green power covers the electricity portion only, while gas, steam, transport, and feedstock emissions remain; certificates and green-power trading may double count; customers apply different recognition rules. A safer statement is "X% of electricity in year Y was covered by green-power trading/certificates, evidence available," with the remaining energy and emissions stated. Never publish a percentage without evidence.
| Route | What it proves | What to keep | Common gap |
|---|---|---|---|
| Self-generation | On-site PV/wind output | Generation meter/grid record | Estimated from capacity |
| Green-power trading | Purchased green electricity | Contract/settlement | No evidence |
| Green certificate | Consumption certificate for the volume | Certificate ID/retirement | Reused |
| Energy-performance contracting | Third-party investment and shared savings | Contract/metering | Ownership unclear |
| Claim boundary | Covers electricity, not all energy | Statement text | "Zero carbon" |
| Double counting | Green power and certificates not both counted | Ledger reconciliation | Counted twice |
Specific accounting and recognition rules follow applicable standards and customer requirements; this article gives no emission factor or offset ratio to avoid conflicting with current rules.
What do customers and auditors look for?
Six evidence groups: energy bills and metering ledgers (where the data comes from), comprehensive-energy and conversion workpapers (how it is calculated), the denominator and boundary for unit-product energy (what it is compared with), the energy management system and responsible person (who owns it), energy audits/online monitoring/annual reports (compliance), and retrofit and green-power evidence (what was done and whether it can be verified). Customers also ask whether data was third-party verified, whether the basis matches the previous version, how abnormal months are explained, and whether obsolete equipment was phased out.
An audit is not "looking at a nice chart" but "following the number to the evidence." If the page says "unit-product energy fell 12%," the auditor will ask for numerator, denominator, period, boundary, factor version, output data, and exception notes. Without them, the number is marketing. The page can provide a "basis note + evidence list + request route"; it need not publish all raw data, but must show the data is verifiable.
| Audit focus | What is requested | Evidence | Common gap |
|---|---|---|---|
| Source | Bills, meters, readings | Raw records | Summary only |
| Calculation | Factors, boundary, formula | Workpaper | No source |
| Denominator | Output basis, period | Production reports | Output/value mixed |
| Management | System, officer, targets | Documents/records | Policy only |
| Compliance | Audit, online monitoring, annual report | Report/screenshot | Missing |
| Retrofit/green | Baseline, verification, certificates | Report/certificate | No verification |
These audit focus points are editorial; the specific document list follows the customer questionnaire, system audit, and contract.
Which claims are exaggerated and should not be published?
High-risk claims include "zero-carbon factory," "100% green power," "energy falls X% every year," "30% savings," and "most energy-efficient in the industry" without boundary, baseline, evidence, and third-party verification. Another risk is mixed bases: output value as denominator, reduced output as savings, theoretical values as measurements, certificates covering all energy, and inconsistent factor versions. Unverified customer cases and unauthorised third-party data should also stay off the public page.
Defensible wording: "comprehensive energy calculated per GB/T 2589," "unit-product energy counted on basis XX," "X% of electricity in year Y covered by green power/certificates, evidence available," "a retrofit tracked for X months, savings calculated per the agreed method." Stating the limits is more credible than an absolute slogan—and more likely to pass a customer audit.
| High-risk claim | Problem | Suggested wording |
|---|---|---|
| Zero-carbon factory | Scope unclear, offsets may be included | State boundary, year, green power/certificates, residual emissions |
| 100% green power | Covers electricity only, not gas/steam/transport | "X% of electricity covered by green power/certificates" |
| Energy down X% | Denominator/boundary/mix unexplained | Give basis, baseline, adjustments |
| 30% savings | No baseline or verification | Give boundary, baseline, tracking period |
| Most efficient | No comparable data | "Better than limit XX / benchmark result" |
| Customer case | Unauthorised/unverified | Obtain consent or anonymise and verify |
These wording limits are editorial; external promotion, advertising, and customer statements also require legal, marketing, and confidentiality review.
What should the page say, and how should it link?
Include energy types and metering, comprehensive energy and conversion basis, the unit-product formula and boundary, key-entity obligations (if applicable), management system and officer, audits/online monitoring/annual reports, retrofits and savings, green power/certificates, a basis note, and a request route for evidence. Link to the carbon-footprint/CBAM page, ESG page, maintenance page, metrology page, and supplier-onboarding page. Publish method and basis, not customer names, full raw data, or unauthorised third-party reports.
Make it a standalone "energy management and unit-product energy" page, not one line in "About us" saying "green factory." Customers search "unit-product energy," "green-power ratio," and "energy audit," and those need a page. Put a direct answer at the top, formulas, boundaries, and an evidence table in the middle, and a data-request route and FAQ at the bottom; sales can use it for questionnaires, EHS for audits, and energy managers for internal targets.
| Module | What to write | Evidence/asset | Common gap |
|---|---|---|---|
| Metering | Types, tiers, meters, verification | Register/certificates | Master meter only |
| Comprehensive energy | Types, conversion, boundary, deductions | Workpaper | No source |
| Unit product | Formula, denominator, mix, comparison | Reports/benchmark | Percentage only |
| Key entity | Status, duties, reports | Report/filing | Not stated |
| Management | System, organisation, targets, training | Documents/records | On the wall |
| Retrofit/green | Baseline, savings, evidence, boundary | Report/certificate | Exaggerated |
| Request/links | Data request, carbon, ESG, maintenance, metrology | Page test | Broken links |
These modules are editorial; public scope, customer data, and wording follow confidentiality requirements and legal/marketing advice.
Go-live acceptance checklist
Ten checks: metering, conversion and boundary, unit-product basis, key-entity obligations, management system and organisation, audits/online monitoring/reports, retrofit baseline and savings, green-power evidence, data evidence chain, and public claims plus links. Each needs an owner, evidence, and review date. The pass condition is not "the page mentions energy saving," but that a customer or auditor can follow the page to the numerator, denominator, factor, boundary, and evidence.
Before go-live, run one production line through: master meter to sub-meters, bill to conversion, output to unit-product energy, retrofit to verified savings, certificate to claim boundary. Any step that fails is a gap in the page or the data.
| Check | Pass condition | Evidence | If it fails |
|---|---|---|---|
| Metering | Segregated/tiered, verified, collected | Register/certificate | Add meters/verify |
| Conversion/boundary | Factor source/version, boundary, deductions, no double count | Workpaper | Recalculate |
| Unit product | Formula, denominator, mix, comparison, explanation | Calculation | Add basis |
| Key entity | Designation, plan, organisation, audit, report | Report/filing | Fulfil duties |
| Management | System, officer, targets, training, audit | Documents/records | Operate it |
| Retrofit | Baseline, boundary, calculation, verification, economics | Project report | Verify |
| Green power | Volume, evidence, boundary, no double count | Trading/certificate | Fix wording |
| Data chain | Bill—meter—ledger—report consistent | Spot check | Add evidence |
| Claims | No unsupported "zero carbon/100%/most efficient" | Page | Remove/revise |
| Links/route | Carbon, ESG, maintenance, metrology reachable; request route | Page test | Fix links |
This checklist is editorial; specific metering, conversion, limits, energy-saving review, and reporting follow the law, standards, authority, and customer requirements.
Who should read this, who should not, and what decisions does it support?
It suits manufacturers in Changzhou and nearby areas with energy targets, customer ESG/carbon questionnaires, export business, or key-entity obligations—especially chemicals, materials, metal processing, equipment, electronics, and continuous production; it also suits teams preparing for an energy audit, green-factory application, customer audit, or retrofit. It does not suit businesses with no production energy use, pure trading companies, or teams wanting one page to replace an energy audit.
Read it if you are in energy, equipment, EHS, finance, procurement, supplier management, or a website vendor; you are building an energy page, cleaning up consumption ledgers, responding to customer questionnaires, preparing an energy audit or green-factory application; or you need to answer "how is comprehensive energy calculated, what is the denominator, are we a key entity, how are savings proven, can green power count as zero carbon." Skip it if you treat "green factory" as a slogan without metering, use theoretical values instead of measurements, or want a page promising "X% reduction every year." It supports self-review of metering, conversion, unit-product energy, key-entity duties, management, retrofits, green power, and claim boundaries.
Lingyi Information is a website development and enterprise AI project provider, not an energy-audit body, energy-diagnosis body, carbon-verification body, or competent authority. This article is not a substitute for energy, energy-saving, carbon-accounting, or legal advice. Changzhou projects are delivered remotely or on site as confirmed per project; Lingyi is one candidate, does not claim a local office or team, and does not promise audit outcomes, subsidies, conversion, or inquiries.
FAQ
How is comprehensive energy calculated, and which conversion factor is used?
Count the physical quantity of each energy type, convert each to standard coal with one consistent factor, and sum; boundary, scope, and conversion follow GB/T 2589-2020. State the factor source, version, and whether it is calorific or equivalent value—do not mix them; avoid double counting electricity and the compressed air it produces, or steam and waste heat. Specific factors follow the current version of the standard; this article gives no fixed number.
How can unit-product energy be compared fairly?
Fix three matching bases first: same boundary, same output basis (conforming product, unit, period), and same product mix (split by product or use a comparable conversion). Then compare with own history, industry benchmarks, and the applicable unit-product energy limit standard. Using output value as the denominator, drifting boundaries, or counting reduced output as savings all distort the result.
If we are not a key energy-using entity, do we still need energy management?
Yes. All energy users must meter, count by category, and keep data true and complete; key entities (≥10,000 tce, or designated 5,000–10,000 tce) also need annual plans, an energy management officer, audits, online monitoring, and annual reports. Customers and the group may apply higher requirements.
Can green power or green certificates count as "zero carbon"?
Not directly. Green power/certificates cover electricity consumption; gas, steam, transport, and feedstock emissions remain. Whether they can be used in a customer's carbon accounting, which factor applies, and whether they double count green-power trading depend on the applicable rules and customer requirements. A safer wording is "X% of electricity in year Y covered by green power/certificates, evidence available."
What basis should we give when a customer asks for energy data?
Give "boundary + period + energy types + factor version + comprehensive energy + denominator + unit-product energy + data source." Also state whether external supply/outsourcing is included, whether third-party verification was done, and whether the basis matches the previous period. A single percentage is unusable and unauditable.
Can the website say "zero-carbon factory" or "100% green power"?
Without a clear boundary, year, evidence, and residual-emission statement, it is not advisable. Write "X% of electricity in year Y covered by green power/certificates," "comprehensive energy calculated per GB/T 2589," or "a retrofit tracked and verified at XX savings." Absolute claims are easy to contradict and will be challenged in a customer audit.
One-sentence takeaway
A Changzhou manufacturer's energy management and unit-product energy page should not sell "green factory, energy saving." It should turn metering, conversion and boundary, unit-product basis, key-entity duties, system and organisation, audits and online monitoring, retrofit baseline and savings, green-power evidence, data chain, and claim boundaries into a verifiable checklist—so a customer or auditor can follow the number to the evidence.
Method and limitations
This is a review of public regulations, standards, and project practice, not a certification or audit opinion on any company, energy data, savings, green-power claim, or audit result. No undisclosed customer ledgers, bills, audit reports, or third-party data were used. Formulas, boundaries, checklists, and the acceptance checklist are editorial suggestions, not energy, energy-saving, carbon-accounting, or legal conclusions. Specific metering, factors, limit standards, energy-saving review, green-power accounting, and customer requirements depend on current rules, standards, the authority, verifiers, and the contract.
Sources and scope
Information is current to 2026-11-02. The following are public official/primary pages; their scope, version, and wording control.
- Energy Conservation Law of the PRC (adopted 1997, revised 2007, second amendment 26 October 2018): Ministry of Ecology and Environment of the PRC. Energy metering and segregated statistics (Art. 27), key energy-using entity designation (Art. 52), annual energy-use report (Art. 53), review and energy audit (Art. 54), energy management officer (Art. 55).
- Measures for Energy Conservation in Key Energy-Using Entities (Order No. 15 of the NDRC and six other departments, effective 1 May 2018): National Development and Reform Commission. Annual plan (Art. 6), management system (Art. 7), targets and assessment (Art. 8), organisation and officer filing (Art. 10), energy audit (Art. 14), online monitoring (Art. 15), retrofits and funding (Art. 16), unit-product limits and benchmarking (Art. 17), energy-saving review (Art. 18).
- GB/T 2589-2020, General Rules for Calculation of the Comprehensive Energy Consumption: National Standards Full-Text Public System. Principles, boundary, scope, calculation method, and conversion to standard coal; specific factors follow the current version of the standard.